Aluminum and aluminum alloy test

1. Purpose
Discovery, control of nonconforming product, take appropriate measures to dispose of non-conforming product to prevent misuse.
2. Scope
Suitable for outsourcing products, finished products and customer returns each process involved in the process name.
3, definition (no)
4. Responsibilities
1) Quality Department is responsible for the discovery of defective recording the identification and isolation, organizations dealing with nonconforming product.
2) Production unit involved in the processing of nonconforming products.
3) Supply Department is responsible for defective products and feed suppliers in touch.
4) The management representative is responsible for defective products approved treatment.
5. oxide type
B3-002
Billet
B3-003
Black anodized
B3-004
Silver anodized
B3-005
Matte silver anodized
B3-006
Matte anodized
B3-007
Bronze anodized
B3-008
Gold anodized
B3-009
Champagne anodized
B3-010
Bright anodizing
B3-011
Black Chemical Oxidation
B3-012
Argent Chemical Oxidation
B3-013
Matte silver Chemical Oxidation
B3-014
Scrub chemical oxidation
B3-015
Bronze chemical oxidation
B3-016
Golden yellow chemical oxidation
B3-017
Champagne chemical oxidation
B3-018
Bright Chemical Oxidation
5, test
5.1 sampling standards
Inspectors in accordance with in accordance with the "GB / T 2828.1-2003 / ISO 259-1: 1999 Sampling procedures for inspection of the first part" of incoming for sampling. Sampling level is generally Ⅱ grade, AQL = 1.5. Passing inspection, inspection records really write and sign the acceptance form; unqualified, fill out the "fill unqualified notice", pay determination in charge.
5.2 test content:
5.2.1 The test incoming packaging meets the requirements. Factory logo is clear and complete.
5.2.2 Control of incoming material inspection and acceptance of a single, model, the code is in line with requirements.
5.2.3 Compliance is checked according to the size of the drawing test, the table did not note dimensional tolerances GB / T 1804-92-M class accuracy test:
 
0.5 ~
3
> 3 ~
6
> 6 ~
30
> 30 ~
120
> 120 ~
400
> 400 ~
1000
> 1000 ~
2000
> 2000 ~
4000
M Accuracy
± 0.1
± 0.1
± 0.2
± 0.3
± 0.5
± 0.8
± 1.2
± 2
5.2.4 Surface appearance test: surface if required drawing lines require uniform thickness, surface cleaning, no obvious scratches, bump hurt, spots and dirt defects and other defects; require the film uniform, continuous, complete, and does not allow film layer loose; the surface may not have hanging gray; the surface is not allowed due to the uneven surface of the alloy, re-oxidation caused by long streak after sanding with fine sandpaper.
5.2.6 test film thickness gage allowed no oxide thin film or an oxide film. General requirements for the oxide film of not less than 4μm.
5.2.7 chemical conductive oxide required to measure its conductivity using a multimeter
5.2.8 electrochemical oxidation (General requirements for sulfuric acid anodizing color) test
The film does not allow visual inspection requirements loose powder, hand rub off the end; do not allow parts of the surface with red spots, or the entire surface or local redness; do not allow partial surface oxide film is etched; Do not allow the part surface easy to stick on fingerprints, watermarks, whitish film
Dimensional inspection Ibid


Prev News:>How to configure the aluminum melting furnace
Next News:>Recycled aluminum: a
| Updated:2015.05.29    Source:    Clicks: